An aluminium mold for intraoperative production of antibiotic-loaded PMMA knee prostheses.

Kohl S, Krueger A, Roeder C, Hartel M, Kohlhof H, Schneider C, Eggli S - Acta Orthop (2009)

View Article: PubMed Central - PubMed

Affiliation: Robert Mathys Foundation, Bettlach, Switzerland. sandro.kohl@rms-foundation.com

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

For treatment of total knee prosthesis infections, a two-stage protocol with explantation of the infected components, antibiotic cement spacer implantation, and secondary reimplantation of the prosthesis after curing the infection is the accepted standard procedure... The cement spacer is antibiotic-loaded, maintains the articular distance between femur and tibia, stabilizes the knee, and allows passive motion of the knee... Such spacers often show insufficient congruency and have a rough surface, which results in instability and excessive wear... Thus, thick scarring of the joint capsule with limited motion is often found at reimplantation, which requires extensive debridement and arthrolysis... The only commercially available molding system is the StageOne Knee Cement Spacer Molds (Biomet Orthopaedics Inc., Warsaw, IN)... This produces significantly better congruency of the articulating parts, with better stability... The main advantages of this system are the stability of the knee after implantation because of the high congruency of the spacer components, and low friction between the articulating surfaces... Thus, almost no PMMA wear particles can be found at reimplantation of the prosthesis... Stability in combination with a low-friction coefficient permits immediate motion training, which results in a substantially better range of motion at reimplantation of a new implant... Other positive attributes include the possibility of adding high doses of antibiotics and the possibility of correct reconstruction of the joint line and the anatomical axis of the leg... Finally, the reusability of the system is cost-efficient.

Show MeSH
After implantation of the PMMA spacer.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC2823218&req=5

Figure 0004: After implantation of the PMMA spacer.

Mentions: Then the distance between the tibia and the femur is measured in neutral position. The tibial mold is filled with PMMA cement according to the distance measured. After polymerization of the cement, the tibial part of the spacer is removed from the mold and the mounting cement on the posterior and lateral side of the spacer is removed with a Luer pincer. The tibial component is then implanted with a small portion of cement (Figure 3). The stability and range of motion is tested, and then the wound can be closed (Figures 4).


An aluminium mold for intraoperative production of antibiotic-loaded PMMA knee prostheses.

Kohl S, Krueger A, Roeder C, Hartel M, Kohlhof H, Schneider C, Eggli S - Acta Orthop (2009)

After implantation of the PMMA spacer.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC2823218&req=5

Figure 0004: After implantation of the PMMA spacer.
Mentions: Then the distance between the tibia and the femur is measured in neutral position. The tibial mold is filled with PMMA cement according to the distance measured. After polymerization of the cement, the tibial part of the spacer is removed from the mold and the mounting cement on the posterior and lateral side of the spacer is removed with a Luer pincer. The tibial component is then implanted with a small portion of cement (Figure 3). The stability and range of motion is tested, and then the wound can be closed (Figures 4).

View Article: PubMed Central - PubMed

Affiliation: Robert Mathys Foundation, Bettlach, Switzerland. sandro.kohl@rms-foundation.com

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

For treatment of total knee prosthesis infections, a two-stage protocol with explantation of the infected components, antibiotic cement spacer implantation, and secondary reimplantation of the prosthesis after curing the infection is the accepted standard procedure... The cement spacer is antibiotic-loaded, maintains the articular distance between femur and tibia, stabilizes the knee, and allows passive motion of the knee... Such spacers often show insufficient congruency and have a rough surface, which results in instability and excessive wear... Thus, thick scarring of the joint capsule with limited motion is often found at reimplantation, which requires extensive debridement and arthrolysis... The only commercially available molding system is the StageOne Knee Cement Spacer Molds (Biomet Orthopaedics Inc., Warsaw, IN)... This produces significantly better congruency of the articulating parts, with better stability... The main advantages of this system are the stability of the knee after implantation because of the high congruency of the spacer components, and low friction between the articulating surfaces... Thus, almost no PMMA wear particles can be found at reimplantation of the prosthesis... Stability in combination with a low-friction coefficient permits immediate motion training, which results in a substantially better range of motion at reimplantation of a new implant... Other positive attributes include the possibility of adding high doses of antibiotics and the possibility of correct reconstruction of the joint line and the anatomical axis of the leg... Finally, the reusability of the system is cost-efficient.

Show MeSH