Radial artery pseudoaneurysm from arterial line placement.

Nguyen DKN - MedPix

View Article: MedPix Image - MedPix Case

Affiliation: Madigan Army Medical Center

ABSTRACT

Diagnosis: Radial artery pseudoaneurysm from arterial line placement.

History: Intensive care patient status post arterial line placement in radial artery, presents with enlarging palpable wrist mass.

Findings: Arterial duplex imaging demonstrates classic sonographic pseudoaneurysm characteristics at the distal 1/3 of the radial artery, which was subsequently treated successfully with ultrasound guided thrombin injection.

Ddx: hematoma, arteriovenous malformation

No MeSH data available.


Pseudoaneurysm treated with thrombin (echogenic) injection.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=MPX1854&req=5

MPX1854_synpic15482: Pseudoaneurysm treated with thrombin (echogenic) injection.


Radial artery pseudoaneurysm from arterial line placement.

Nguyen DKN - MedPix

Pseudoaneurysm treated with thrombin (echogenic) injection.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=MPX1854&req=5

MPX1854_synpic15482: Pseudoaneurysm treated with thrombin (echogenic) injection.

View Article: MedPix Image - MedPix Case

Affiliation: Madigan Army Medical Center

ABSTRACT

Diagnosis: Radial artery pseudoaneurysm from arterial line placement.

History: Intensive care patient status post arterial line placement in radial artery, presents with enlarging palpable wrist mass.

Findings: Arterial duplex imaging demonstrates classic sonographic pseudoaneurysm characteristics at the distal 1/3 of the radial artery, which was subsequently treated successfully with ultrasound guided thrombin injection.

Ddx: hematoma, arteriovenous malformation

No MeSH data available.