Example cases of plate and screws after failure of fixation. When volar plate fixation was performed without radial styloid screws, both ulnar fragment screws were broken while radial fragment screws remained intact (radial styloid screw -). In contrast, both ulnar screws remained intact when volar plate fixation was performed using 2 radial styloid screws (radial styloid screw +).
© Copyright Policy

Figure 6: Example cases of plate and screws after failure of fixation. When volar plate fixation was performed without radial styloid screws, both ulnar fragment screws were broken while radial fragment screws remained intact (radial styloid screw -). In contrast, both ulnar screws remained intact when volar plate fixation was performed using 2 radial styloid screws (radial styloid screw +).

Mentions: Figure 6 shows example of plates and screws after the experiments. In cases of volar plate fixation without radial styloid screws, both 2 ulnar fragment screws were broken while the radial fragment screws remained no broken. In contrast, both ulnar screws remained intact in cases of volar plate fixation with 2 radial styloid screws.

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

Iba K, Ozasa Y, Wada T, Kamiya T, Yamashita T, Aoki M - J Orthop Surg Res (2010)

Bottom Line: The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment.Data for ultimate strength and screw failure after failure loading were compared between the 2 groups.After failure loading, the average change in gap between the ulnar and proximal fragment was greater than that between the radial and proximal fragment.

Affiliation: Department of Orthopaedic Surgery School of Medicine, Sapporo Medical University. iba@sapmed.ac.jp.

ABSTRACT

Background: The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the radial styloid screws using a biomechanical study in a cadaver fracture model.

Methods: Six matched pairs of fresh-frozen human cadaver wrists complete from the proximal forearm to the metacarpal bones were prepared to simulate standardized 3-part intra-articular and severe comminuted fractures. Specimens were fixed using the volar plating system with or without 2 radial styloid screws. Each specimen was loaded at a constant rate of 20 mm/min to failure. Load data was recorded and, ultimate strength and change in gap between distal and proximal fragments were measured. Data for ultimate strength and screw failure after failure loading were compared between the 2 groups.

Results: The average ultimate strength at failure of the volar plate fixation with radial styloid screws (913.5 ± 157.1 N) was significantly higher than that without them (682.2 ± 118.6 N). After failure loading, the average change in gap between the ulnar and proximal fragment was greater than that between the radial and proximal fragment. The number of bent or broken screws in ulnar fragment was higher than that in radial fragment. The number of specimens with bent or broken screws in cases with radial styloid screws was fewer than that in the fixation without radial styloid screws group.

Conclusion: The ulnar fragment is more intensively stressed than the radial fragment under axial loading of distal radius at full wrist extension. The radial styloid screws were effective in stable volar plate fixation of distal radial fractures.

View Similar Images In: Results Collection              View Article: Pubmed Central HTML PubMed      Show All Figures 
getmorefigures.php?pmc=3014894&rFormat=json&query=null&fields=all&favor=none&it=none&sub=none&sp=none&coll=none&lic=none&vid=none&req=5
Show MeSH

Lister Hill National Center for Biomedical Communications
U.S. National Library of Medicine, 8600 Rockville Pike, Bethesda, MD 20894
National Institutes of Health, Department of Health & Human Services
Privacy, Accessibility, Frequently Asked Questions, Contact Us, Collection
Freedom of Information Act, USA.gov